Home / Video and data cables
Product line 03

High speed video cable manufacturer

Video assemblies for displays, docking and equipment links. HDMI Type A, Type C and Type D plugs, 20-pin DisplayPort and USB-C video, built to your drawing with coaxial high speed pairs, controlled impedance and the rated bandwidth held over the length you actually order.

10 to 48 Gbps 100 ohm differential Coaxial high speed pairs Moulded or die-cast shell
Interfaces

Connectors we build on

The connector decides the tooling and the pair count. The bandwidth column is what the assembly is built to hold over its finished length, not what a source at the other end might send.

Video and data interfaces, by physical connector
ConnectorPinsTypical productBandwidth we build to
HDMI Type A19TV, monitor, console, set-top box10.2 / 18 / 48 Gbps
HDMI Type C, mini19Cameras, compact devices10.2 Gbps
HDMI Type D, micro19Cameras, embedded links10.2 Gbps
DisplayPort, 20 pin20Monitor, dock, daisy chain21.6 / 32.4 Gbps
USB-C, video alt mode24Dock, portable monitorup to 40 Gbps

The figure is aggregate across the high speed lanes, because that is how the lanes are used. A cable that reaches its top rate only on a short bench sample is a cable sold on a number rather than built to one, which is why we quote the rate against a length.

The part that decides the rate

Shielding and impedance, not copper weight

At video rates the limiting factor is rarely how much copper is in the conductor. It is whether the pair holds its differential impedance along the whole run, and whether the shield keeps the outside world out of a signal that is measured in millivolts.

A twisted pair is good enough at 10 Gbps. Past that, each high speed lane wants its own coaxial construction: a solid dielectric around the conductor, a bonded foil wrap, and a drain path that terminates at both plugs rather than floating at one end.

Two things kill an otherwise correct build. A shield that stops short of the shell, leaving an unshielded gap right where the cable flexes, and an impedance mismatch at the transition from cable to plug. Both are tooling and process decisions, not inspection findings.

What we specify at quotation. The pair construction, the differential impedance window, shield coverage and the drain termination, against the finished length you order. If the drawing names a rate we cannot hold at that length in passive copper, we say so before tooling rather than after the first shipment.

JACKET BRAID COAX PAIR DRAIN + FILLER SECTION B-B
Four high speed lanes, each on its own coaxial construction. The shield has to reach the shell, or the last few millimetres of the assembly undo the rest of it.
Rate against length

How far a passive cable actually goes

Every rate has a length past which passive copper stops holding. Asking for both is a normal request, and the answer is sometimes a different construction rather than a longer cable.

Practical passive length, by aggregate rate
RatePractical passive lengthWhat changes to go longer
10.2 Gbpsup to 10 mLarger conductor, tighter impedance window
18 Gbps3 to 5 mHeavier shield, more pair isolation
32.4 Gbps1.5 to 3 mCoaxial pairs, tighter bend radius
48 Gbps1 to 2 mAn active element or an optical run

These are working numbers for passive copper, not the ceiling of what the interface can define. Lengths past them are built with an active element, and we will quote that as a different assembly rather than promising the passive one will perform.

Construction

What goes into the specification

Construction options, confirmed per drawing
ElementOptionsEffect
High speed pairsCoaxial, shielded twisted pair, 28 to 34 AWGRate ceiling and how well it holds over length
Differential impedance100 Ω ±10 %, tighter on requestReflections at the plug transition
ShieldBonded foil, braid, foil plus braid, 85 % braid coverage and upEMI ingress and crosstalk between lanes
Drain termination360° crimp to shell, or terminated at one end by designWhether the shield actually works
JacketPVC, TPE, TPU, braided nylon over TPEFlex life, hand feel, retail look
ShellOvermoulded PVC, die-cast zinc, aluminiumRetention, heat spread, perceived quality
ContactsGold flash, 15µin, 30µin over nickelInsertion cycles before resistance climbs
Bend radius4× OD static, 8× OD in flexing useWhether the shield survives the install

Connector shells, contact plating and pair construction are the three lines that decide whether a video cable still works in month eighteen. Length and colour are the easy ones.

Durability

What fails first, and how it gets specified

A video cable usually dies at the two ends, not in the middle. These are the four checks that predict it, and each one is a number you can put on a drawing.

Wear tests and typical targets
TestWhat it measuresTypical target
Flex and swingConductor fatigue and jacket splitting at the strain relief5,000 to 10,000 cycles at ±60°
Mating cyclesContact plating wear and shell retention10,000 insertions
Pull forceHow much load the moulded end takes before it separates50 N held for one minute
Temperature riseHeating at the contacts under the rated currentunder 30 °C above ambient

Flex and mating tests are destructive, so they are quoted per request and the report names the sample size. Quoting a cycle count without a test behind it is exactly the kind of claim this page is trying not to make.

Questions

Video cables, asked directly

Why does the same cable run at a lower rate on one device?

The link settles at the highest rate every element in the chain supports, and the cable is only one element. A display that tops out lower, a source with a weaker transmitter, or a repeater in the middle will pull the whole negotiation down. Two cables can measure identically on a bench and behave differently on a long run, because the margin is in the eye pattern, not the spec sheet.

How long can a 48 Gbps cable be?

Passive copper is practical at one to two metres. Three metres is the edge of what holds without help, and it depends on the pair construction and the plug. Past that an active element or an optical run is the honest answer. Anyone quoting a five metre passive 48 Gbps cable is either measuring something else or has not tested it on a real sink.

Does the shield have to cover the whole cable?

It has to cover the whole signal path and reach the shell at both ends. A shield that stops ten millimetres short of the plug leaves an unshielded window exactly where the cable flexes, which is where the failures come from. Braid coverage above 85 % with a bonded foil underneath is the usual construction for the higher rates.

Can you build a cable that only carries video, with no return channel?

Yes, if your drawing leaves those conductors out. It reduces the pair count and the cost, and it is a common request for equipment links where the protocol never uses the return path. It also means the assembly will not work with a consumer source that expects that channel, so the decision belongs on the drawing rather than in a conversation after the samples arrive.

Do you build active and optical assemblies?

We build passive copper in the lengths on this page. For active or optical runs we quote against a module supplier's reference design rather than treating it as a passive cable with a chip added. Tell us the rate and the length and we will say which of the two it has to be.

Can you match a video cable we already buy?

Send a sample. We measure conductor gauge and pair construction, section the overmould to see what the tooling has to reproduce, and check where the shield terminates. We will tell you where the existing part is under-specified, because copying a design that fails at eighteen months is not a service.

Send the rate and the length

Tell us the connector pair, the rate you need to hold, the finished length and the device it plugs into. We will come back with unit price, the pair construction we would use, and whether passive copper gets there.